All applications where capturing both temperature and humidity data is important
The LogTag® Humidity & Temperature Recorder measures and stores up to 8000 sets of high resolution humidity and temperature readings over 0 to 100%RH & -40 °C to +85 °C measurement ranges.
Using the LogTag® Interface and LogTag's freely available companion software LogTag® Analyzer, the LogTag® is easily set-up for recording conditions including delayed start, sampling interval, number of readings, continuous or fixed number of readings and configuration of conditions to activate the ALERT indicator. Readings are downloaded using LogTag® Analyzer which provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as Excel.
Please note: An interface is required for configuration and reporting
Part Order Code | HAXO-8 |
Humidity Measurement range | 0 ~ 100 % RH but with limitations as detailed in Humidity Measurement Operating and Storage conditions below |
Temperature Measurement range | -40 ~ +85 °C |
Humidity Resolution | better than 0.1 % RH |
Temperature Resolution | better than 0.1 °C |
Capacity | 8000 pairs of humidity & temperature readings (32 Kbytes memory) |
Sampling frequency | adjustable, 30 sec to several hours |
Download Time | Typically with full memory in less than 10 seconds depending on computer or readout device used. |
Environmental | IP61 (when hung or mounted vertically) |
Power source | 3V LiMnO2 Battery |
Battery life | 2~3 years typical use |
Size | 86 mm (H) x 54,5 mm (B) x 8,6 mm (T) |
Weight | 35 grams |
Case Material | Polycarbonate |
*Optimal Storage Condition | For optimal Humidity logger storage, store units in original packaging in an air conditioned area. Storage temperature shall be in the range of 10°C to 50°C and humidity at 20 %RH to 60 %RH. Ensure good ventilation (fresh air supply) in storage area to avoid high concentrations of volatile chemicals. Do not store units in the same room as solvents or any other strong smelling products. |
LogTag® Recorders reserves the right to change this product's specifications without notice.
|
This chart shows the normal recommended operating range of the humidity sensor.
Conditions outside the recommended range may temporarily offset the RH signal up to ±3 % RH. After return to normal conditions it will slowly return towards calibration state by itself. See section "Re-Conditioning Procedure" in the data sheet to accelerate this process. Prolonged exposure to extreme conditions may accelerate ageing.