The LogTag TICT is a low cost disposable electronic temperature indicator for use in monitoring temperature & time statistics in transport applications of up to 45 days duration.
The LogTag TICT can monitor and record statistics against four factory pre-set temperature limits for up to 45 days, displaying a tick mark if environmental conditions remain within limits. If temperatures exceed two high temperature alarm limits or go below two low temperature alarm limits, the LCD shows a REJECT alert, indicating the goods require further checking.
The LogTag TICT is factory pre-configured for one of a range of monitoring profiles. Special profiles are available on request, subject to conditions.
Statistical data can be downloaded from the TICT using the LogTag Indicator interface cradle and freely available LogTag Analyzer operating software if required.
The TICT offers an accurate and cost effective solution for monitoring the cold chain in "last mile" distribution and other applications where full data logging capability is not required.
Ready Mode Push the START/STOP button. "Ready" shows that the indicator is ready to be started.
Start delay mode Press and hold the START/STOP button. "RUN" will flash. Release button when flashing stops. The Indicator now begins the preset start delay.
Run Mode "RUN" appears on the display. The indicator is now taking a temperature reading at the factory stipulated interval (typically every 5 minutes). If an Alarm occurs the symbol is replaced by an X symbol and the corresponding alarm limit code (HT1, HT2, LT1 or LT2) is also displayed.
Stopped Mode Press and Hold the START/STOP button. "Stopped" will flash. Release button when flashing stops. The Indicator now no longer takes readings.
Factory Configurations LogTag TICT can be factory configured to support a large range of different monitoring and alarm configurations (see specifications over page for details).
Example configuration
Operating Temperature Range -25 °C to +60 °C
Storage Temperature Range -25 °C to 65 °C
Ambient humidity range during transport and use 0 to 95 % RH
Resolution 0.1 °C or better in range of -25 °C to +60 °C
Accuracy
Capacity
Memory type Non volatile
Sampling Interval Factory set as required. Typically to 5 minute interval.
Logging modes 45 day statistics, temperature/time excursions and Alarm trigger time and duration for each day
Logging Start delay Factory configuration, typically set to 60 minute interval
Sensor Precision thermistor
Sensor Reaction time T90 less than 7 minutes by method detailed in EN12830:1999
Vibration Withstands vibration specification as detailed in EN12830:1999
Shock
Environmental IEC 60529: IP64
Power source 3 V Lithium battery - non replaceable
Battery life:
Size 71.5 mm (H) x 33.0 mm (B) x 8.6 mm (T) (Volume <21 cm3)
Weight 19 g
Case Material Polycarbonate
Calibration Traceable to an ISO/IEC 17025 accredited testing laboratory, to NIST, or to another internationally recognized standards agency
EMV compliance
Alarms function & display